000119552 001__ 119552
000119552 005__ 20190228220120.0
000119552 0247_ $$2doi$$a10.1109/77.614524
000119552 022__ $$a1051-8223
000119552 02470 $$2ISI$$aA1997XH86400080
000119552 037__ $$aARTICLE
000119552 245__ $$aPerformance of the quench detection system for ITER
000119552 260__ $$c1997
000119552 269__ $$a1997
000119552 336__ $$aJournal Articles
000119552 500__ $$aPart 1
000119552 520__ $$aThe purpose of this study is to assess the expected response of conventional and non-conventional quench detection sensors proposed for the ITER coils. The assessment is based on simulation of thermo-hydraulic transients in the coils for various operating conditions, and a tentative definition of the transfer functions of each sensor concept. For the investigated conditions, the co-wound voltage tap shows the best performance of the six sensors which are analyzed.
000119552 6531_ $$aITER
000119552 700__ $$0240107$$g105759$$aMarinucci, C.
000119552 700__ $$aBottura, L.
000119552 700__ $$aPourrahimi, S.
000119552 700__ $$aZhelamskij, M.
000119552 773__ $$j7$$tIeee Transactions on Applied Superconductivity$$k2$$q443-446
000119552 909CO $$pSB$$particle$$ooai:infoscience.tind.io:119552
000119552 909C0 $$pCRPP
000119552 909C0 $$0252028$$pSPC$$xU12272$$xU12268$$xU10558$$xU10635$$xU12266$$xU10636$$xU10137$$xU12270$$xU10557$$xU12273$$xU10559$$xU12271$$xU12269$$xU12267$$xU10136
000119552 937__ $$aCRPP-ARTICLE-1997-030
000119552 973__ $$rREVIEWED$$sPUBLISHED$$aEPFL
000119552 980__ $$aARTICLE