On the use of transmission line theory to represent a nonuniform vertically-extended object struck by lightning

In this study, we present an experimental validation of the transmission line representation of an elevated object struck by lightning. The experimental results are obtained using a reduced-scale model and injected signals with narrow pulse widths (down to 500 ps). The validation is performed using a reduced scale structure representing the Toronto CN Tower in Canada. Two models consisting, respectively, of 1-section and 3-section uniform transmission lines were considered for the comparison. It is shown that the 3-section model is able to accurately reproduce the obtained experimental data. The overall agreement between the 1-section model and the experimental results is also satisfactory, at least for the early-time response


Published in:
Proceedings of 2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)
Presented at:
2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446), 2003
Year:
2003