Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Ligament balancing in TKA: Evaluation of a force-sensing device and the influence of patellar eversion and ligament release
 
research article

Ligament balancing in TKA: Evaluation of a force-sensing device and the influence of patellar eversion and ligament release

Crottet, Denis
•
Kowal, Jens
•
Sarfert, Sven A.
Show more
2007
Journal of Biomechanics

Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus–valgus loading. Four different experiments were performed on each specimen. (1) Knee joints were axially loaded. Comparison between applied and measured compressive forces demonstrated the accuracy and reliability of in situ measurements (1.8 N). (2) Assessment of knee stability based on condyle contact forces or varus–valgus moments were compared to the current surgical method (difference of varus–valgus loads causing condyle lift-off). The force-based approach was equivalent to the surgical method while the moment-based, which is considered optimal, showed a tendency of lateral imbalance. (3) To estimate the importance of keeping the patella in its anatomical position during imbalance assessment, the effect of patellar eversion on the mediolateral distribution of tibiofemoral contact forces was measured. One fourth of the contact force induced by the patellar load was shifted to the lateral compartment. (4) The effect of minor and major medial collateral ligament release was biomechanically quantified. On average, the medial contact force was reduced by 20% and 46%, respectively. Large variation among specimens reflected the difficulty of ligament release and the need for intraoperative force monitoring. This series of experiments thus demonstrated the device’s potential to improve ligament balancing and survivorship of total knee arthroplasty. Keywords: Force-sensing device; Ligament balancing; Ligament release; Total knee arthroplasty

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

2007 Crottet - capteur genou - knee sensor - postprint.pdf

Type

Postprint

Version

http://purl.org/coar/version/c_ab4af688f83e57aa

Access type

openaccess

Size

2 MB

Format

Adobe PDF

Checksum (MD5)

d5639c212b2b1ae856c78f48afafcbb7

Loading...
Thumbnail Image
Name

2007 Crottet capteur genou mesures médicales.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

restricted

Size

391.65 KB

Format

Adobe PDF

Checksum (MD5)

7e3c448dc775f693bb26bd14de41cdb0

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés