Punching shear strength of R/C bridge cantilever slabs

Vaz Rodrigues, Rui
•
Fernández Ruiz, Miguel  
•
Muttoni, Aurelio  
2008
Engineering Structures

This paper presents the results of six tests on R/C bridge cantilever slabs without shear reinforcement subjected to concentrated loading. The specimens represent actual deck slabs of box-girder bridges scaled 3/4. They were 10mlong with a clear cantilever equal to 2.78mand with variable thickness (190mm at the tip of the cantilever and 380 mm at the clamped edge). Reinforcement ratios for the specimens were equal to 0.78% and 0.60%. All tests failed in a brittle manner by development of a shear failure surface around the concentrated loads. The experimental results are investigated on the basis of linear elastic shear fields for the various tests. Taking advantage of the experimental and numerical results, practical recommendations for estimating the shear strength of R/C bridge cantilever slabs are proposed.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

Vaz08a.pdf

Access type

openaccess

Size

1.91 MB

Format

Adobe PDF

Checksum (MD5)

061640b95b6c759a308d88c3c60e92c3

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés