Buried & surface cofiring compatibility of DuPont 5092D PTC thermistor composition with DuPont 951 LTCC

Dumontier, Nicolas
•
Maeder, Thomas  
2008

This reports documents qualification tests made with the 100Ω PTC resistive composition DuPont (DP) 5092D, co-fired on the surface and inside (buried) DP 951 LTCC material, using a wide range of Ag & alloyed Ag-Pd conductor termination: DP 6142D & 6145 (Ag), and 6135D & 6143 & 6146 & 7484 (Ag-Pd). These tests were deemed necessary, as previous ones [1], carried out with Ag terminations only, were deemed not conclusive and reliable enough. The resulting resistors were electrically characterised, and the reliability of the different samples was analysed. Besides, the degree of deformation and morphology of the samples was qualitatively evaluated.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

2008-11-19 Qualification DP 5092D LTCC DP 951.pdf

Type

Publisher's Version

Version

Published version

Access type

openaccess

Size

907.41 KB

Format

Adobe PDF

Checksum (MD5)

a8ac074f0b994131209af8c5b07e0427

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés