Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Ion coalescence in Fourier transform mass spectrometry: should we worry about this in shotgun proteomics?
 
research article

Ion coalescence in Fourier transform mass spectrometry: should we worry about this in shotgun proteomics?

Tarasova, Irina A.
•
Surin, Alexey K.
•
Fornelli, Luca  
Show more
2015
European Journal Of Mass Spectrometry

Coupling of motion of the ion clouds with close m/z values is a well-established phenomenon for ion-trapping mass analyzers. In Fourier transform ion cyclotron resonance mass spectrometry it is known as ion coalescence. Recently, ion coalescence was demonstrated and semiquantitatively characterized for the Orbitrap mass analyzer as well. When it occurs, the coalescence negatively affects the basic characteristics of a mass analyzer. Specifically, the dynamic range available for the high resolving power mass measurements reduces. In shotgun proteomics, another potentially adverse effect of ion coalescence is interference of the isotopic envelopes for the coeluting-precursor ions of close m/z values, subjected to isolation before fragmentation. In this work we characterize coalescence events for synthetic-peptide mixtures with fully and partially overlapping C-13-isotope envelopes, including pairs of peptides with glutamine-deamidation. Furthermore, we demonstrate that fragmentation of the otherwise coalesced peptide ion clouds may remove the locking between them owing to the total charge redistribution between more ion species in the mass spectrum. Finally, we estimated the possible-scale of the coalescence phenomenon for shotgun proteomics by considering the fraction of coeluted peptide pairs with the close masses using literature data for the yeast proteome. It was found that up to one-tenth of all peptide identifications with the relative mass differences of 20 ppm or less in the corresponding pairs may potentially experience the coalescence of the C-13-isotopic envelopes. However, sample complexity in a real proteomics experiment and precursor ion-signal splitting between many channels in tandem mass spectrometry drastically increase the threshold for coalescence, thus leading to practically coalescence-free proteomics based on Fourier transform mass spectrometry.

  • Details
  • Metrics
Type
research article
DOI
10.1255/ejms.1356
Web of Science ID

WOS:000364826200040

Author(s)
Tarasova, Irina A.
Surin, Alexey K.
Fornelli, Luca  
Pridatchenko, Marina L.
Suvorina, Mariya Yu.
Gorshkov, Mikhail V.
Date Issued

2015

Publisher

Im Publications

Published in
European Journal Of Mass Spectrometry
Volume

21

Issue

3

Start page

459

End page

470

Subjects

orbitrap

•

ion coalescence

•

shotgun proteomics

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LSMB  
Available on Infoscience
February 16, 2016
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/123683
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés