Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Enhancement of actuation ability of ionic-type conducting polymer actuators using metal ion implantation
 
research article

Enhancement of actuation ability of ionic-type conducting polymer actuators using metal ion implantation

Alici, Gursel
•
Punning, Andres  
•
Shea, Herbert R.  
2011
Sensors and Actuators B: Chemical

In this study, we present the results and implications of an experimental study into the effect of gold-ion implantation on the actuation performance of ionic-type conducting polymer actuators, represented here by cantilevered tri-layer polypyrrole (PPy) actuators. We implant gold ions beneath the outer surfaces of PPy-based conducting polymer layers of the actuators in order to increase the conductivity of these layers, and therefore improve the overall conductivity of the actuators. A Filtered Vacuum Cathode Arc (FVCA) ion source was used to implant gold particles into the conducting polymer layers. Electrode resistance and capacitance, surface resistance, current response, mechanical work output of the actuator samples were measured and/or calculated for the actuator samples with and without gold implantation in order to demonstrate the effect of the gold-implantation. The current passing through the conducting polymer electrodes during their ‘electrochemomechanical’ actuation was measured to determine the charging time constant of the actuators. The mechanical displacement output of the actuators was recorded. The results demonstrate that the conductivity of the actuators increases noticeably, which has a flow on effect on the current response (i.e., charge injected into the polymer layers) and the mechanical work output. While the gold implanted actuators had a higher mechanical stiffness therefore a smaller displacement output, their time constant is smaller, indicating a higher response speed. The gold-implanted actuators generated a 15% higher mechanical work output despite the adverse effects on the polymer of the vacuum processing needed for the ion implantation.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

alici ionic.pdf

Access type

openaccess

Size

3.62 MB

Format

Adobe PDF

Checksum (MD5)

e45ef7576a98ece17ab4b31392fb531f

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés