Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. On the use of extents for process monitoring and fault diagnosis
 
conference paper not in proceedings

On the use of extents for process monitoring and fault diagnosis

Srinivasan, Sriniketh  
•
Billeter, Julien  
•
Bonvin, Dominique  
2014
14th Conference on Chemometrics in Analytical Chemistry (CAC)

Process monitoring and fault diagnosis are broadly used to control quality and enforce safety compliance in industrial processes. Processes are commonly monitored by online spectroscopy, with either PCA or calibration techniques such as PLS being used to predict abstract or physical process variables. By comparing these variables to historical data measured under normal operating conditions, possible faults are detected based on deviations from statistical thresholds [1]. One then tries to identify the causes of these faults, identification being easier when monitoring involves a calibration that predicts physical process variables and when fault detection uses a model to relate controlled and manipulated variables [2]. <br><br> Exploiting the structure of balance equations, a transformation can separate multivariate data into decoupled variant/invariant states, which can be investigated individually to identify rate laws and reconstruct unmeasured quantities [3]. A convenient linear transformation uses the generalized concept of extents [4, 5], which coincides with a time-invariant transformation used to model rank-deficient spectroscopic data [6]. This transformation requires only limited process information, namely, the reaction stoichiometry, the species transferring between phases, the composition of inlet flows and the initial conditions. Moreover, this transformation was adapted to handle calorimetric and spectroscopic data [7, 8]. <br><br> This contribution addresses the applicability of the transformation to extents for process monitoring and fault diagnosis. By comparing the extents computed from measurements of the current batch with either their prediction or the extents computed from previous batches, significant deviations can point at possible faults and provide a systematic way of identifying their causes. <br><br> <b>References:</b><br> [1] Venkatasubramanian et al., Comp. Chem. Eng. 27 (2003) 327 <br> [2] Venkatasubramanian et al., Comp. Chem. Eng. 27 (2003) 293 <br> [3] Srinivasan et al., IFAC Proceedings Vol. 1 (2013) 102 <br> [4] Amrhein et al., AIChE J. 56 (2010) 2873 <br> [5] Bhatt et al., Ind. Eng. Chem. Res. 49 (2010) 7704 <br> [6] Billeter et al., Chemom. Intell. Lab. Syst. 95 (2009) 170 <br> [7] Srinivasan et al., Chem. Eng. J. 207-208 (2012) 785 <br> [8] Billeter et al., Anal. Chim. Acta 767 (2013) 21

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

Abstract CAC 2014.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

openaccess

Size

11.42 KB

Format

Adobe PDF

Checksum (MD5)

6b19cc436d6d6780920d2ce5213c2327

Loading...
Thumbnail Image
Name

Srinivasan et al. CAC 2014.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

openaccess

Size

1.51 MB

Format

Adobe PDF

Checksum (MD5)

43ac9b927c1fd56fc60cafa6cef62ad7

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés