  4. Advanced single voxel 1 H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations
 
research article

Advanced single voxel 1 H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations

Öz, Gülin
•
Deelchand, Dinesh K.
•
Wijnen, Jannie P.
Show more
January 10, 2020
NMR in Biomedicine

Conventional proton MRS has been successfully utilized to noninvasively assess tissue biochemistry in conditions that result in large changes in metabolite levels. For more challenging applications, namely, in conditions which result in subtle metabolite changes, the limitations of vendor-provided MRS protocols are increasingly recognized, especially when used at high fields (>/=3 T) where chemical shift displacement errors, B0 and B1 inhomogeneities and limitations in the transmit B1 field become prominent. To overcome the limitations of conventional MRS protocols at 3 and 7 T, the use of advanced MRS methodology, including pulse sequences and adjustment procedures, is recommended. Specifically, the semiadiabatic LASER sequence is recommended when TE values of 25-30 ms are acceptable, and the semiadiabatic SPECIAL sequence is suggested as an alternative when shorter TE values are critical. The magnetic field B0 homogeneity should be optimized and RF pulses should be calibrated for each voxel. Unsuppressed water signal should be acquired for eddy current correction and preferably also for metabolite quantification. Metabolite and water data should be saved in single shots to facilitate phase and frequency alignment and to exclude motion-corrupted shots. Final averaged spectra should be evaluated for SNR, linewidth, water suppression efficiency and the presence of unwanted coherences. Spectra that do not fit predefined quality criteria should be excluded from further analysis. Commercially available tools to acquire all data in consistent anatomical locations are recommended for voxel prescriptions, in particular in longitudinal studies. To enable the larger MRS community to take advantage of these advanced methods, a list of resources for these advanced protocols on the major clinical platforms is provided. Finally, a set of recommendations are provided for vendors to enable development of advanced MRS on standard platforms, including implementation of advanced localization sequences, tools for quality assurance on the scanner, and tools for prospective volume tracking and dynamic linear shim corrections.

  • Details
  • Metrics
Type
research article
DOI
10.1002/nbm.4236
PubMed ID

31922301

Author(s)
Öz, Gülin
Deelchand, Dinesh K.
Wijnen, Jannie P.
Mlynárik, Vladimír
Xin, Lijing  
Mekle, Ralf
Noeske, Ralph
Scheenen, Tom W.J.
Tkáč, Ivan
Date Issued

2020-01-10

Published in
NMR in Biomedicine
Issue

[Epub ahead of print]

Article Number

e4236

Subjects

CIBM-AIT

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
CIBM  
LIFMET  
Available on Infoscience
January 14, 2020
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/164597
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés