Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Proxies to monitor the inactivation of viruses by ozone in surface water and wastewater effluent
 
research article

Proxies to monitor the inactivation of viruses by ozone in surface water and wastewater effluent

Wolf, Camille  
•
Pavese, Annalisa
•
von Gunten, Urs  
Show more
September 13, 2019
Water Research

Ozone treatment is an effective barrier against viral pathogens, therefore it is an integral part of many water and wastewater treatment trains. However, the efficacy of ozone treatment remains difficult to monitor, due to the lack of methods to track virus inactivation in real-time. The goal of this work was to identify easy-to-measure proxies to monitor virus inactivation during water and wastewater treatment by ozone. Proxies considered were the abatement in UV absorbance at 254 nm (UV254) and carbamazepine (CBZ), a ubiquitous organic micropollutant with a similar abatement rate constant as human viruses. The proxies, as well as the inactivation of two viruses (MS2 coliphage and coxsackievirus B5) were measured in surface water and in a secondary wastewater effluent as a function of the specific ozone dose (mgO3/mg dissolved organic carbon). Virus inactivation was rapid in both matrices, but was more efficient in surface water. This trend was also evident when inactivation was assessed as a function of the ozone exposure to account for the different ozone demand of the two water types. Both proxies, as well as the specific ozone dose, were correlated with virus inactivation. The correlations depended only weakly on the virus species, but – with the exception of CBZ abatement – differed between the two water types. Finally, predictive relationships were established using Bayesian power models, to estimate virus inactivation based on the measurement of a proxy. The models were then applied to estimate the MS2 inactivation in a pilot-scale ozone reactor that treats surface water of Lake Zurich. All proxies yielded good estimates of the actual MS2 inactivation in the pilot plant, indicating that the proxy-inactivation relationships established in the laboratory can also be applied to flow-through reactors. This study confirms that ozone is a highly effective disinfectant for viruses in both surface water and wastewater, and that the abatement of UV254 and CBZ can be used to track virus inactivation during water and wastewater treatment.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1016/j.watres.2019.115088
Author(s)
Wolf, Camille  
Pavese, Annalisa
von Gunten, Urs  
Kohn, Tamar  
Date Issued

2019-09-13

Published in
Water Research
Volume

166

Article Number

115088

Subjects

ozone

•

disinfection

•

coxsackievirus B5

•

MS2

•

proxy

•

wastewater

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LEV  
LTQE  
FunderGrant Number

FNS

SNF

FNS

205321_169615

Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/161158
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés