Long-term trends of primary and secondary pollutant concentrations in Switzerland and their response to emission controls and economic changes

Kuebler, J.
•
van den Bergh, H.  
•
Russell, A. G.
2001
Atmospheric Environment

A de-trending technique was developed for short-term and annual variations to identify long-term trends in primary and secondary pollutants. With this approach, seasonal and annual variations are removed using a mean year; the residual meteorol. short-term variation is removed using a multiple linear regression model. This method was used to de-trend O3, NOx, volatile org. compd. (VOC) and CO concns. in Switzerland. Primary pollutants (NOx, VOC, CO) at urban and suburban stations exhibited a downward trend over the last decade which correlates well with redns. in estd. Swiss emissions. Despite large decreases achieved in precursor emissions, summer peak O3 concns. did not show any statistically significant trend over the last decade. Applying this method to O3 concns. measured at the Jungfraujoch (3580 m above sea level) also showed no trend over the last 10 yr. De-trended summer O3 correlated well with European Union gross national product and industrial prodn. growth rates. These results suggested that if substantial redns. in summer peak O3 in Switzerland are desired, emissions redn. strategies must be part of control programs involving a much larger region.

  • Details
  • Metrics
Type
research article
DOI
10.1016/S1352-2310(00)00401-5
Author(s)
Kuebler, J.
•
van den Bergh, H.  
•
Russell, A. G.
Date Issued

2001

Published in
Atmospheric Environment
Volume

35

Issue

8

Start page

1351

End page

1363

Subjects

10028-15-6 (Ozone) Role: FMU (Formation

•

unclassified)

•

PEP (Physical

•

engineering or chemical process)

•

POL (Pollutant)

•

FORM (Formation

•

nonpreparative)

•

OCCU (Occurrence)

•

PROC (Process) (de-trending method to assess effect of emission controls and e

•

primary secondary air pollution trend Switzerland

•

emission control effect primary secondary air pollutant

•

economic change effect primary secondary air pollutant

•

nitrogen oxide carbon monoxide air pollution trend

•

volatile org compd ozone air pollutio

Note

Copyright 2003 ACS

CAPLUS

AN 2001:110382

CAN 134:284861

59-2

Air Pollution and Industrial Hygiene

53

Swiss Federal Institute of Technology,Lausanne,Switz. FIELD URL:

Journal

AENVEQ

written in English.

Air pollution (de-trending method to assess effect of emission controls and economic changes on long-term trends of primary and secondary air pollutants in Switzerland); Volatile organic compounds Role: POL (Pollutant), OCCU (Occurrence) (de-trending method to assess effect of emission controls and economic changes on long-term trends of primary and secondary air pollutants in Switzerland); Simulation and Modeling (meteorol. conditions; de-trending method to assess effect of emission controls and economic changes on long-term trends of primary and secondary air pollutants in Switzerland); Air pollution (photochem.; de-trending method to assess effect of emission controls and economic changes on long-term trends of primary and secondary air pollutants in Switzerland)

Altshuler, S; Journal of the Air and Waste Management Association 1995, 45, 967|Baltensperger, U; Journal of Geophysical Research 1997, 102, 19707|Bronimann, S; Atmospheric Environment 1997, 31, 1127|Clappier, A; European project COST 615-CITAIR, http://dgrwww.epfl.ch/PAS/MOD/study/cost/ 1997|Eidgenossische Komission fur Lufthygiene; Ozone in der Schweiz 1993|Eskridge, R; Bulletin of the American Meteorological Society 1997, 78, 1473|Flaum, J; Journal of the Air and Waste Management Association 1996, 46, 35|Gardner, M; Atmospheric Environment 1999, 34, 171|Graf-Jaccotet, M; Environmetrics 1998, 9, 393|Kahn, M; A Report for the Georgia Department of Natural Resources 2000|Kuebler, J; Atmospheric Environment 1996, 30, 951|Lau, K; Bulletin of the American Meteorological Society 1995, 76, 239|Lugauer, M; Tellus 1998, 50B, 76|Milanchus, M; Presentation at the Air and Waste Management Association's 90th Annual Meeting 1997|Neu, U; Boundary-Layer Meteorology 1994, 69, 221|Perego, S; Research Report for the Canton Obwald, http://dgrwww.epfl.ch/PAS/MOD/obwald 1999|Rao, S; Journal of the Air and Waste Management Association 1994, 44, 1089|SAEFL; Emissions Polluantes dues a l'Activite Humaine en Suisse de 1900 a 2010 1995|SAEFL; NABEL 1998|Stohl, A; Atmospheric Environment 2000, 34, 1323|Swiss Federal Office of Energy; Statistique globale suisse de l'energie 1997 1998|Swiss Federal Office of Energy; Apercu de la consommation d'energie en suisse au cours de l'annee 1998 1999|Thomas, J; Georgia Undergraduate Research Report 2000|Venables, W; Modern Applied Statistics with S-PLUS 1998|Wilks, D; International Geophysics Series 1995, 59|Zanis, P; Atmospheric Environment 1999, 33, 3777|Zurbenko, I; International Statistical Review 1991, 59, 163

Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LPAS  
Available on Infoscience
February 1, 2011
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/63810
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés