Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. A Quality-Scalable and Energy-Efficient Approach for Spectral Analysis of Heart Rate Variability
 
conference paper not in proceedings

A Quality-Scalable and Energy-Efficient Approach for Spectral Analysis of Heart Rate Variability

Karakonstantis, Georgios  
•
Sankaranarayanan, Aviinaash
•
Aly, Mohamed Mostafa Sabry  
Show more
2014
Design Automation & Test in Europe (DATE)

Today there is a growing interest in the integration of health monitoring applications in portable devices necessitating the development of methods that improve the energy efficiency of such systems. In this paper, we present a systematic approach that enables energy-quality trade-offs in spectral analysis systems for bio-signals, which are useful in monitoring various health conditions as those associated with the heart-rate. To enable such trade-offs, the processed signals are expressed initially in a basis in which significant components that carry most of the relevant information can be easily distinguished from the parts that influence the output to a lesser extent. Such a classification allows the pruning of operations associated with the less significant signal components leading to power savings with minor quality loss since only less useful parts are pruned under the given requirements. To exploit the attributes of the modified spectral analysis system, thresholding rules are determined and adopted at design- and run-time, allowing the static or dynamic pruning of less-useful operations based on the accuracy and energy requirements. The proposed algorithm is implemented on a typical sensor node simulator and results show up-to 82% energy savings when static pruning is combined with voltage and frequency scaling, compared to the conventional algorithm in which such trade-offs were not available. In addition, experiments with numerous cardiac samples of various patients show that such energy savings come with a 4.9% average accuracy loss, which does not affect the system detection capability of sinus-arrhythmia which was used as a test case.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

DATE_14_219_Karakonstantis.pdf

Type

Preprint

cris-layout.advanced-attachment.oaire.version

http://purl.org/coar/version/c_71e4c1898caa6e32

Access type

openaccess

Size

1.01 MB

Format

Adobe PDF

Checksum (MD5)

f01b31c2a566118021545ce6cf9de03d

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés