Loading...
research article
Pressure drop and helium inlet in ITER CS1 conductor
A number of pressure drop measurements have been carried out at CRPP on a section of ITER cable-in-conduit conductor, using pressurized water at room temperature. The longitudinal friction factor is deduced for the strand bundle area and the central hole. Two layouts of radial helium inlet have been investigated and the measured radial pressure drop is assessed in terms of the equivalent conductor length producing the same pressure drop in axial direction. (C) 2001 Elsevier Science B.V. All rights reserved.
Type
research article
Web of Science ID
WOS:000172991100036
Authors
Publication date
2001
Published in
Volume
58-9
Start page
211
End page
215
Subjects
Peer reviewed
REVIEWED
Available on Infoscience
April 16, 2008
Use this identifier to reference this record