  4. Partial Discharge Localization Using Electromagnetic Time Reversal: A Performance Analysis
 
research article

Partial Discharge Localization Using Electromagnetic Time Reversal: A Performance Analysis

Azadifar, Mohammad
•
Karami, Hamidreza  
•
Wang, Zhaoyang  
Show more
2020
IEEE Access

In this study, first, a comparison on the application of electromagnetic time reversal (EMTR) and time difference of arrival (TDoA) in partial discharge localization in power transformers is presented. A two-dimensional finite-difference time-domain simulation is used to calculate the signal recorded by the sensors. Results show that, in a transformer tank excluding its windings, both methods yield similar results in terms of location accuracy, although the EMTR method only needs one sensor to localize the partial discharge (PD) source while the TDoA method needs at least three sensors in the 2D localization problem. However, the presence of transformer windings leads to a degradation of the performance of the TDoA method if the line of sight from the source to the sensor is blocked by any of the winding blocks. On the other hand, the presence of the transformer windings has an effect on the localization of PD sources that occur between two adjacent phase windings when the distance between the outer winding distances is shorter than the minimum wavelength, λmin . The degradation is directly caused by the diffraction limit. It is shown that, if the distance between two adjacent phase windings is greater than λmin , the EMTR process can locate PD sources occurring between two adjacent phase windings with acceptable accuracy. A case of occurrence of PDs in close proximity (less than λmin /2) to a single metallic object is analyzed both numerically and experimentally. The analysis reveals that although a degradation in the accuracy of the localization is observed compared to the case of longer distances between the PD source and the metallic object, a reasonable localization error of 10 mm (corresponding to λmin /10) is obtained.

  • Files
  • Details
  • Metrics
Type
research article
DOI
10.1109/ACCESS.2020.3015973
Author(s)
Azadifar, Mohammad
Karami, Hamidreza  
Wang, Zhaoyang  
Rubinstein, Marcos
Rachidi, Farhad
Karami, Hossein
Ghasemi, Ali  
Gharehpetian, Gevork B.
Date Issued

2020

Published in
IEEE Access
Volume

8

Start page

147507

End page

147515

Subjects

Experimental analysis

•

Partial discharge localization

•

Time difference of arrival

•

Electromagnetic time reversal

•

Transformer tank

Note

This article is licensed under a Creative Commons Attribution 4.0 International License

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
SCI-STI-FR  
UPDEPALMA  
Available on Infoscience
August 20, 2020
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/170985
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés