Analysis and modeling of electrostatic discharge in a tactile glass featured watch
Electrostatic discharge (ESD) in quartz watches is becoming more and more important due to the use of plastic materials and tactile sensors. The discharge can lead to different type of dysfunction such as a simple reset, a latch-up or the destruction of the electronics In this paper, only the reversible dysfunction is considered. Electrostatic finite element (FEM) simulation completed with analytical calculation are carried out. Spatial distribution of the voltages will be shown. Values of the discrete elements are determined either by the electrostatic FEM (capacitors) or by analytical methods. Validation of the theory is done by DC (resistors) and AC (impedance) measurements. The watch is then modeled with these discrete impedances forming a global equivalent circuit in order to simulate its dynamic behavior. Results will show the discharge propagation on key components like the micro-controller 1C.
2-s2.0-10944236269
2004
2
1287
1293
Laboratory of Integrated Actuators, Swiss Fed. Institute of Technology, 1015 Lausanne, SwitzerlandService Unit RD, ETA SA Manufacture Horlogere Suisse, Swatch Group, 2540 Grenchen, Switzerland
Cited By: 0; Export Date: 15 May 2006; Source: Scopus