Simultaneous Chemical Recording and Stimulation in the Brain Using an Assembly of Biosensor Silicon Microprobes and SU-8 Microinjectors
In this contribution we present multi-channel microinjector arrays fabricated by a reliable three-layer SU-8 process and assembled with glutamate biosensor microprobes'. It enables local delivery of specific liquids into brain tissue for the stimulation or inhibition of neuronal activity combined with simultaneous monitoring of biochemical substances. Real-time measurements in the prefrontal cortex of the rats' brain demonstrate the successful in vivo calibration of the biosensor responding to pressure injections of small volumes of the neurotransmitter glutamate in its local vicinity.
WOS:000275995600267
2009
Procedia Chemistry
1
525
528
REVIEWED
EPFL
Event name | Event place | Event date |
Lausanne, SWITZERLAND | Sep 06-09, 2009 | |