  4. Rapid, Sensitive and Selective Optical Glucose Sensing with Stimulated Raman Scattering (SRS)
 
conference paper

Rapid, Sensitive and Selective Optical Glucose Sensing with Stimulated Raman Scattering (SRS)

Golparvar, Ata  
•
Boukhayma, Assim  
•
Enz, Christian  
Show more
January 1, 2022
2022 Ieee International Symposium On Medical Measurements And Applications (Memea 2022)
17th IEEE International Symposium on Medical Measurements and Applications (IEEE MeMeA)

Optical blood glucose sensing offers pain-free, non-invasive, continuous monitoring with minimum risk of infection since it does not require breaking the skin barrier. Among various optical detection and spectroscopic techniques, only Raman scattering offers both high-accuracy and chemical-specific acquisition along with label-free sensing. However, spontaneous Raman scattering is a feeble process. The integration time is long and high laser intensities are demanded to achieve acceptable sensitivity in detecting physiologically relevant glucose levels. This hinders the inherent advantages of Raman scattering-based technologies as a wearable medical point-of-care device. Therefore, this study applies stimulated Raman scattering (SRS) to glucose sensing, which overcomes the limitations of spontaneous Raman spectroscopy. This is the first study demonstrating the application of SRS in glucose concentration monitoring. Herein, by enhancing the Raman effect using stimulating excitation, we have recorded a linear calibration curve for concentrations below 100 mol/m(3) with a theoretical limit of detection (LOD) of 33 mol/m(3) in a phenomenal 0.6 s integration time merely by employing univariate data analysis. In addition, we have assessed the optimum required averaged laser power and sensing mechanism's feasibility in complete human serum glucose measurement and established a highly selective detection mechanism by solely identifying the characteristic Raman shift peak of glucose around 1130 cm(-1).

  • Details
  • Metrics
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés