  4. Signal fluctuations in fMRI data acquired with 2D-EPI and 3D-EPI at 7 Tesla
 
research article

Signal fluctuations in fMRI data acquired with 2D-EPI and 3D-EPI at 7 Tesla

Jorge, João
•
Figueiredo, Patrícia
•
van der Zwaag, Wietske  
Show more
2012
Magnetic resonance imaging

Segmented three-dimensional echo planar imaging (3D-EPI) provides higher image signal-to-noise ratio (SNR) than standard single-shot two-dimensional echo planar imaging (2D-EPI), but is more sensitive to physiological noise. The aim of this study was to compare physiological noise removal efficiency in single-shot 2D-EPI and segmented 3D-EPI acquired at 7 Tesla. Two approaches were investigated based either on physiological regressors (PR) derived from cardiac and respiratory phases, or on principal component analysis (PCA) using additional resting-state data. Results show that, prior to physiological noise removal, 2D-EPI data had higher temporal SNR (tSNR), while spatial SNR was higher in 3D-EPI. Blood oxygen level dependent (BOLD) sensitivity was similar for both methods. The PR-based approach allowed characterization of relative contributions from different noise sources, confirming significant increases in physiological noise from 2D to 3D prior to correction. Both physiological noise removal approaches produced significant increases in tSNR and BOLD sensitivity, and these increases were larger for 3D-EPI, resulting in higher BOLD sensitivity in the 3D-EPI than in the 2D-EPI data. The PCA-based approach was the most effective correction method, yielding higher tSNR values for 3D-EPI than for 2D-EPI postcorrection.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.mri.2012.07.001
Web of Science ID

WOS:000314440900006

Author(s)
Jorge, João
Figueiredo, Patrícia
van der Zwaag, Wietske  
Marques, José P.
Date Issued

2012

Publisher

Elsevier Science Inc

Published in
Magnetic resonance imaging
Volume

31

Issue

2

Start page

212

End page

20

Subjects

Signal fluctuations

•

Physiological noise

•

Segmented 3D-EPI

•

BOLD fMRI

•

Ultra-high field

•

CIBM-AIT

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
CIBM  
LIFMET  
Available on Infoscience
February 9, 2013
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/88743
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés