  4. Field solar E-coli inactivation in the absence and presence of TiO2: is UV solar dose an appropriate parameter for standardization of water solar disinfection?
 
research article

Field solar E-coli inactivation in the absence and presence of TiO2: is UV solar dose an appropriate parameter for standardization of water solar disinfection?

Rincon, A. G.
•
Pulgarin, C.  
2004
Solar Energy

Evaluation of solar treatment in the absence and presence of TiO2 has been made to assess its effectiveness in reducing bacterial load with respect to drinking water standards. Field experiments under direct solar radiation were carried out using a compound parabolic collector (CPC) placed at the Swiss Federal Institute of Technology (EPFL), Lausanne, Switzerland. Water contaminated with E coli K12 was exposed to sunlight in different seasons. The obtained results indicate that the presence of TiO2 accelerates the detrimental action of light. Total photocatalytic disinfection was obtained in both periods of year and no bacterial recovery was observed during 24h after stopping sunlight exposure. In the absence of TiO2, total disinfection was not always reached; and bacterial recovery was observed, especially when inactivation was not complete. Bacterial decay was mainly dependent on light intensity. It was also demonstrated that solar UV dose is not a pertinent parameter to standardize solar disinfection. The influence of the following topics on solar water disinfection is also studied in this paper: (a) UV and total solar spectra characteristics (b) volume of phototreated water (c) post-irradiation events. (C) 2004 Elsevier Ltd. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.solener.2004.08.002
Web of Science ID

WOS:000225694200020

Author(s)
Rincon, A. G.
Pulgarin, C.  
Date Issued

2004

Published in
Solar Energy
Volume

77

Issue

5

Start page

635

End page

648

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LBE  
GPAO  
Available on Infoscience
October 18, 2005
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/217868
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés